Selection Guide: Interior
Filter By:
Interior expansion joint covers from EMSEAL are designed to maximize durability and coordinate aesthetically. How to select floor expansion joints?
*Stock Item: These are short-lead-time items stocked by EMSEAL in quantities usually sufficient to meet project demands. If not in stock EMSEAL will provide an import quote and lead time.
Exterior Vertical Wall
Description
- Primary Seal
- R-Value
- Sound Attenuation
- Available in many industry standard colors
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Single installation seals both sides of joint
- Ideal for curtainwall, precast
- Customized to depth of substrate
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Primary seal in paintable STPE or silicone
- Smooth convex surface
- Low cost
- Rapid install alternative to caulk & backer rod
Details
1/2″ to 1 1/4″
(12 – 30mm)
80% Movement (+30%/ -50%)
Description
- Watertight and fire rated
- 1-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry standard colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Watertight and fire rated
- 3-Hour, Built-In Fire-Rating (UL 2079)
- For concrete, concrete block or gypsum walls
- Many industry standard colors
Details
1/2″ to 6″
(12 – 150mm)
50% Movement (+25%/-25%)
Description
- Pick-resistant
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Secondary Seal to Field Applied Liquid Sealant
Details
1/4″ to 1 1/4″
(6 – 30mm)
50% Movement (+25/-25%)
Description
- Acrylic-modified asphaltic impregnated foam
- Primary seal
- Black in color
Details
1/4″ – 4″
(6 – 100mm)
50% Movement (+25/-25%)
Description
- Primary Seal
- R-Value
- Sound Attenuation
- 26 colors
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- CE marked movement joint for EU and other markets requiring CE marking
- Not available in North America
- Vertical or Horizontal Plane Primary Seal
Details
12mm to 200mm
(1/2” – 8”)
100% movement (+50%/-50%)
Available in Sikasil WS295 colors
Fire-Rated Interior and Exterior Wall
Description
- Watertight and fire rated
- 1-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry standard colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Watertight and fire rated
- 3-Hour, Built-In Fire-Rating (UL 2079)
- For concrete, concrete block or gypsum walls
- Many industry standard colors
Details
1/2″ to 6″
(12 – 150mm)
50% Movement (+25%/-25%)
Description
- Pick-resistant
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Sika/Emseal Sole Source
Description
A warranty offering for the US market that combines Sikalastic DeckPro and Emseal Expansion Joint systems under a Sole Source Warranty.
Details
This system offers the following advantages:
1. Traffic membrane and expansion joint supplied and backed by a single manufacturer.
2. Backed by a manufacturer in business for over 100 years.
3. Tested and proven details to ensure the system will work.
4. Local representatives available to work with local contractors.
Stadium Seating Bowl
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Decks/Parking
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- 3-Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
50% Movement (+25%/-25%)
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Joint Face Adhered
- Non-trafficable
- Wide range of industry-standard colors
Details
1/2″ to 8″
(12 – 200mm)
100% Movement (+50%/-50%)
Description
- pick-resistant floor joint
- 2-hour, built-in fire-rating (UL 2079)
- watertight
- non-invasively anchored
- joint-face adhered
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- pick resistant floor joint
- 3-hour, built-in fire-rating (UL 2079)
- non-invasively anchored
- joint face adhered
Details
1/2″ to 4″
(12 – 100mm)
50% Movement (+25%/-25%)
Description
- High-Impact Elastomeric Concrete Material
- Nosing to build or repair gap edges
- Self-leveling and Noise Dampening
- Fast-curing durable concrete patch
Details
Any Size
Description
A warranty offering for the US market that combines Sikalastic DeckPro and Emseal Expansion Joint systems under a Sole Source Warranty.
Details
This system offers the following advantages:
1. Traffic membrane and expansion joint supplied and backed by a single manufacturer.
2. Backed by a manufacturer in business for over 100 years.
3. Tested and proven details to ensure the system will work.
4. Local representatives available to work with local contractors.
Description
- Double-sided DSM
- Silicone-coated on both faces
- Simple installation in unique applications
Details
1/2″ to 4″
(12 – 200mm)
(Larger sizes consult Emseal)
Description
- CE marked movement joint for EU and other markets requiring CE marking
- Not available in North America
- Vertical or Horizontal Plane Primary Seal
Details
12mm to 200mm
(1/2” – 8”)
100% movement (+50%/-50%)
Available in Sikasil WS295 colors
Stadium Concourse -- Solid Slab
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Fire-Rated Deck and Floor
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- 3-Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
50% Movement (+25%/-25%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- pick-resistant floor joint
- 2-hour, built-in fire-rating (UL 2079)
- watertight
- non-invasively anchored
- joint-face adhered
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- pick resistant floor joint
- 3-hour, built-in fire-rating (UL 2079)
- non-invasively anchored
- joint face adhered
Details
1/2″ to 4″
(12 – 100mm)
50% Movement (+25%/-25%)
Stadium Concourse -- Split Slab
Description
- Watertight
- Watertight integration with deck waterproofing membrane
- Factory heat-welded transitions ensure continuity of seal
- Optional coverplates
Details
Up to 4.75-inch (120mm)
max. mean joint
Movement varies with model
Description
- Watertight integration into buried waterproofing membranes
- Silicone coated, precompressed foam and integral aluminum spline, sealing assembly
- Integral coverplate
Details
up to 16″
(400mm)
max. mean joint
100% Movement (+50%/-50%)
Description
- For split-slabs, plaza decks, podium decks
- Up to 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Ideal for plaza to solid slab conditions
- Watertight integration at structural slab
- Silicone coated, precompressed foam sealing element
- Optional coverplates
Details
up to 4″
(100mm)
max. mean joint
100% Movement (+50%/-50%)
Split Slab/Plaza
Description
- Watertight
- Watertight integration with deck waterproofing membrane
- Factory heat-welded transitions ensure continuity of seal
- Optional coverplates
Details
Up to 4.75-inch (120mm)
max. mean joint
Movement varies with model
Description
- Watertight integration into buried waterproofing membranes
- Silicone coated, precompressed foam and integral aluminum spline, sealing assembly
- Integral coverplate
Details
up to 16″
(400mm)
max. mean joint
100% Movement (+50%/-50%)
Description
- For split-slabs, plaza decks, podium decks
- Up to 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Ideal for plaza to solid slab conditions
- Watertight integration at structural slab
- Silicone coated, precompressed foam sealing element
- Optional coverplates
Details
up to 4″
(100mm)
max. mean joint
100% Movement (+50%/-50%)
Description
- For fire-rated, split-slabs, plaza decks, podium decks
- 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
up to 4″
(100mm)
max. mean join
100% Movement (+50%/-50%)
Description
- High movement
- Redundant sealing and fastening
- Double-level roof-membrane integration flanges
- UV-stable
Details
RJ-0200: 2-3 inches (50-75mm)
RJ-0400: 3-5 inches (75-125mm)
RJ-0600: 5-7 inches (125-175mm)
RJ-0800: 7-9 inches (175-225mm)
Movement
RJ-0200: 2 1/2 inches (60mm)
RJ-0400: 5 inches (125mm)
RJ-0600: 7 inches (175mm)
RJ-0800: 9 inches (225mm)
Fire-Rated Split Slab and Plaza Deck
Description
- For split-slabs, plaza decks, podium decks
- Up to 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Precast Connections and Small Joints
Fire-Rated
Description
- For split-slabs, plaza decks, podium decks
- Up to 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- For fire-rated, split-slabs, plaza decks, podium decks
- 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
up to 4″
(100mm)
max. mean join
100% Movement (+50%/-50%)
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- 3-Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
50% Movement (+25%/-25%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- pick-resistant floor joint
- 2-hour, built-in fire-rating (UL 2079)
- watertight
- non-invasively anchored
- joint-face adhered
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- pick resistant floor joint
- 3-hour, built-in fire-rating (UL 2079)
- non-invasively anchored
- joint face adhered
Details
1/2″ to 4″
(12 – 100mm)
50% Movement (+25%/-25%)
Description
- Watertight and fire rated
- 1-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry standard colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Watertight and fire rated
- 3-Hour, Built-In Fire-Rating (UL 2079)
- For concrete, concrete block or gypsum walls
- Many industry standard colors
Details
1/2″ to 6″
(12 – 150mm)
50% Movement (+25%/-25%)
Description
- Pick-resistant
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- For fire-rated tunnel linings
- RWS compliant
- Up to 2 hour built-in fire rating
Details
1/2″ to 4″ | 6 – 100mm
100% Movement (+50%/-50%)
Fire Rated Tunnels
Stadium Walls
Description
- Primary Seal
- R-Value
- Sound Attenuation
- Available in many industry standard colors
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Single installation seals both sides of joint
- Ideal for curtainwall, precast
- Customized to depth of substrate
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Primary seal in paintable STPE or silicone
- Smooth convex surface
- Low cost
- Rapid install alternative to caulk & backer rod
Details
1/2″ to 1 1/4″
(12 – 30mm)
80% Movement (+30%/ -50%)
Description
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Pick-resistant
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Roof
Description
- High movement
- Redundant sealing and fastening
- Double-level roof-membrane integration flanges
- UV-stable
Details
RJ-0200: 2-3 inches (50-75mm)
RJ-0400: 3-5 inches (75-125mm)
RJ-0600: 5-7 inches (125-175mm)
RJ-0800: 7-9 inches (175-225mm)
Movement
RJ-0200: 2 1/2 inches (60mm)
RJ-0400: 5 inches (125mm)
RJ-0600: 7 inches (175mm)
RJ-0800: 9 inches (225mm)
Description
When Emseal’s Roofjoint product is used in conjunction with Hydrotech’s Monolithic Membrane 6125® (MM6125®) waterproofing/roofing membrane, Hydrotech can provide a true single source Watertightness Warranty for up to 20 years.
Details
- watertight tie-in to MM6125 hot applied rubberized asphalt waterproofing membrane
- Redundant sealing across the joint opening
- Allows drainage across the joint opening
- Redundant dual-level roof-membrane integration
Below Grade
Description
- Extruded Nitrile-PVC extrusion with dual-level membrane integration flanges
- Flanges are welded or adhered to below-grade waterproofing membrane and fastened with termination bar and anchors
- Transitions to RoofJoint in softscapes, and FP-Systems in hardscapes
Details
2″ up to 7″
(50 – 175mm)
Stadium Interior Floors
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 4″ (10 – 100mm)
Movement:
1 1/2″= +3/4″, -3/4″
(40mm= +20mm, -20mm)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 3″ (10 – 75mm)
Movement:
1 1/8″= +9/16″, -9/16″
(30mm= +15mm, -15mm)
Interior
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 4″ (10 – 100mm)
Movement:
1 1/2″= +3/4″, -3/4″
(40mm= +20mm, -20mm)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 3″ (10 – 75mm)
Movement:
1 1/8″= +9/16″, -9/16″
(30mm= +15mm, -15mm)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 2″ (10 – 50mm)
Movement:
¾″= +3/8″, -3/8″
(20mm= +10mm, -10mm)
Description
Alum/rubber
Recessed mount
Standard load rating
Details
Joint sizes:
13/16″ – 2″ (20 – 50mm)
Movement:
3/4″= + 3/8″, – 3/8″
(20mm= +10mm, -10mm)
Description
Alum/elastomeric
Recess mount
Standard load rating
Details
Joint size:
½″ – 2″ (13 – 50mm)
Movement:
5/8″= +5/16″, -5/16″
16mm= +8mm, -8mm
Description
Solid aluminum
Surface mount
Details
Joint sizes:
½″ – 3 ¼″ (13 – 80mm)
Movement:
Max open joint: 3 ¼″ (80mm)
Min closed joint: ¼″ (7mm)
Description
Alum/elastomeric
Recess mount
Standard load rating
Details
Joint sizes:
3/16″ – 1 ¼″ (5 – 30mm)
Movement:
3/8″= +3/16″, -3/16″
(10mm= +5mm, -5mm)
Description
Alum/rubber
Surface mount
Standard load rating
Details
Joint sizes:
3/4″ – 1 1/4″ (20 – 30mm)
Movement:
3/16″= + 1/8″, – 1/16″
(5mm= +3mm, -2mm)
Description
Alum/elastomeric
Surface mount
Standard load rating
Details
Joint sizes:
1 3/8″ – 1 7/8″ (35 – 48mm)
Movement:
3/8″= + 3/16″, – 3/16″
(10mm= +5mm, -5mm)
Description
Alum/elastomeric
Surface mount
Standard load rating
Details
Joint size:
2″ – 2 ½″ (50 – 65mm)
Movement:
5/8″= + 5/16″, – 5/16″
(16mm= +8mm, -8mm)
Description
Solid Aluminum
Extra heavy load rating
Details
Joint sizes:
Up to 24″ (820mm)
Movement:
Various
Description
Precompressed
Anchorless
Rapid installation
Details
Joint sizes:
1″ – 4″ (25 – 100mm)
Movement:
Up to 100% (+50, -50%)
Stadium Roofs
Description
- High movement
- Redundant sealing and fastening
- Double-level roof-membrane integration flanges
- UV-stable
Details
RJ-0200: 2-3 inches (50-75mm)
RJ-0400: 3-5 inches (75-125mm)
RJ-0600: 5-7 inches (125-175mm)
RJ-0800: 7-9 inches (175-225mm)
Movement
RJ-0200: 2 1/2 inches (60mm)
RJ-0400: 5 inches (125mm)
RJ-0600: 7 inches (175mm)
RJ-0800: 9 inches (225mm)
Below-grade / Foundation
Description
- Extruded Nitrile-PVC extrusion with dual-level membrane integration flanges
- Flanges are welded or adhered to below-grade waterproofing membrane and fastened with termination bar and anchors
- Transitions to RoofJoint in softscapes, and FP-Systems in hardscapes
Details
2″ up to 7″
(50 – 175mm)
Acoustic
Immersed
Description
- Silicone-coated, pre-compressed
- New or Retrofit
- Chlorine and saline resistant
- Resists head pressure
Details
1/2″ to 4″
(12 – 100mm)
50% Movement (+25%/-25%)
Description
- Chemical resistant
- Watertight
- Non-Invasive Anchoring
Details
1/2″ to 2″ (12mm to 50mm) for up to 5-feet of head pressure; up to 4″ (100mm) for larger sizes
50% Movement (+25%/-25%)
Description
- Silicone-bellows sealing surface compliant to NSF/ANSI Standard 61 for contact with potable drinking water and for indirect contact with food
- Will not pose a contamination risk to liquids or solids which may be ingested
Details
1/2″ to 8″ (12mm to 200mm) for walls; 1/2″ to 4″ (12mm to 100mm) for floors
50% Movement (+25%/-25%)
Stadium
Description
- Primary Seal
- R-Value
- Sound Attenuation
- Available in many industry standard colors
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Extruded Nitrile-PVC extrusion with dual-level membrane integration flanges
- Flanges are welded or adhered to below-grade waterproofing membrane and fastened with termination bar and anchors
- Transitions to RoofJoint in softscapes, and FP-Systems in hardscapes
Details
2″ up to 7″
(50 – 175mm)
Description
- Watertight
- Watertight integration with deck waterproofing membrane
- Factory heat-welded transitions ensure continuity of seal
- Optional coverplates
Details
Up to 4.75-inch (120mm)
max. mean joint
Movement varies with model
Description
- Watertight integration into buried waterproofing membranes
- Silicone coated, precompressed foam and integral aluminum spline, sealing assembly
- Integral coverplate
Details
up to 16″
(400mm)
max. mean joint
100% Movement (+50%/-50%)
Description
- For split-slabs, plaza decks, podium decks
- Up to 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Ideal for plaza to solid slab conditions
- Watertight integration at structural slab
- Silicone coated, precompressed foam sealing element
- Optional coverplates
Details
up to 4″
(100mm)
max. mean joint
100% Movement (+50%/-50%)
Description
- For fire-rated, split-slabs, plaza decks, podium decks
- 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
up to 4″
(100mm)
max. mean join
100% Movement (+50%/-50%)
Description
- High movement
- Redundant sealing and fastening
- Double-level roof-membrane integration flanges
- UV-stable
Details
RJ-0200: 2-3 inches (50-75mm)
RJ-0400: 3-5 inches (75-125mm)
RJ-0600: 5-7 inches (125-175mm)
RJ-0800: 7-9 inches (175-225mm)
Movement
RJ-0200: 2 1/2 inches (60mm)
RJ-0400: 5 inches (125mm)
RJ-0600: 7 inches (175mm)
RJ-0800: 9 inches (225mm)
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Single installation seals both sides of joint
- Ideal for curtainwall, precast
- Customized to depth of substrate
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Primary seal in paintable STPE or silicone
- Smooth convex surface
- Low cost
- Rapid install alternative to caulk & backer rod
Details
1/2″ to 1 1/4″
(12 – 30mm)
80% Movement (+30%/ -50%)
Description
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Pick-resistant
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Primary Seal
- R-Value
- Sound Attenuation
- 26 colors
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 4″ (10 – 100mm)
Movement:
1 1/2″= +3/4″, -3/4″
(40mm= +20mm, -20mm)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 3″ (10 – 75mm)
Movement:
1 1/8″= +9/16″, -9/16″
(30mm= +15mm, -15mm)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 2″ (10 – 50mm)
Movement:
¾″= +3/8″, -3/8″
(20mm= +10mm, -10mm)
Transitions
Description
- Watertight expansion joint transitions
- Continuity of seal through plane and direction changes
- Watertight transitions between different technologies
Details
- Roof to wall transitions
- Wall to below grade transitions
- Deck/floor to wall transitions
- Step and tread/riser transitions
- Below-grade to plaza
- Continuity of fire protection at plane changes
Description
When Emseal’s Roofjoint product is used in conjunction with Hydrotech’s Monolithic Membrane 6125® (MM6125®) waterproofing/roofing membrane, Hydrotech can provide a true single source Watertightness Warranty for up to 20 years.
Details
- watertight tie-in to MM6125 hot applied rubberized asphalt waterproofing membrane
- Redundant sealing across the joint opening
- Allows drainage across the joint opening
- Redundant dual-level roof-membrane integration
Description
- Factory-fabricate universal or custom transitions for precompressed foam sealant products
- Universal (reversible as upturn or downturn) or Custom-Made to field measurements
- For use in parking, stadium, interior or exterior applications
Details
- Factory-fabrication removes risk of field errors
- Installs faster than can be made in the field
- Ensures continuity of seal — guaranteed
- Available in watertight-only and fire-rated
Single-Source Warranties
Description
When Emseal’s Roofjoint product is used in conjunction with Hydrotech’s Monolithic Membrane 6125® (MM6125®) waterproofing/roofing membrane, Hydrotech can provide a true single source Watertightness Warranty for up to 20 years.
Details
- watertight tie-in to MM6125 hot applied rubberized asphalt waterproofing membrane
- Redundant sealing across the joint opening
- Allows drainage across the joint opening
- Redundant dual-level roof-membrane integration
Description
A warranty offering for the US market that combines Sikalastic DeckPro and Emseal Expansion Joint systems under a Sole Source Warranty.
Details
This system offers the following advantages:
1. Traffic membrane and expansion joint supplied and backed by a single manufacturer.
2. Backed by a manufacturer in business for over 100 years.
3. Tested and proven details to ensure the system will work.
4. Local representatives available to work with local contractors.