Selection Guide: Stadium
Stadium expansion joint solutions - watertight from foundation, to concourses, to walls, seating bowl and roof.
Stadium Seating Bowl
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Stadium Concourse -- Solid Slab
Description
- 2 -Hour, Built-In Fire-Rating (UL 2079)
Details
1/2″ to 4″
(12 – 100mm)
100% Movement (+50%/-50%)
Description
- Joint face adhered
- Sound-dampening-nosing blockouts available
- Integral coverplate
- Non-invasively anchored
Details
2″ to 16″
(50 – 400mm)
100% Movement (+50%/-50%)
Stadium Concourse -- Split Slab
Description
- Watertight
- Watertight integration with deck waterproofing membrane
- Factory heat-welded transitions ensure continuity of seal
- Optional coverplates
Details
Up to 4.75-inch (120mm)
max. mean joint
Movement varies with model
Description
- Watertight integration into buried waterproofing membranes
- Silicone coated, precompressed foam and integral aluminum spline, sealing assembly
- Integral coverplate
Details
up to 16″
(400mm)
max. mean joint
100% Movement (+50%/-50%)
Description
- For split-slabs, plaza decks, podium decks
- Up to 2-hour built-in fire-rating
- Watertight integration with deck waterproofing membrane
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
- Ideal for plaza to solid slab conditions
- Watertight integration at structural slab
- Silicone coated, precompressed foam sealing element
- Optional coverplates
Details
up to 4″
(100mm)
max. mean joint
100% Movement (+50%/-50%)
Precast Connections and Small Joints
Stadium Walls
Description
- Retrofit joint sealant for EIFS, precast, concrete, and virtually any substrate
- Safe and rapid installation without the requirement for grinding
- Smooth convex surface
- Paintable and coatable
Details
1/2″ to 1 1/4″
(12 – 30mm)
100% movement (+/- 50%)
Use in Joint Range:
3/8” – 1-1/2”
(10 – 40mm)
Description
- Primary Seal
- R-Value
- Sound Attenuation
- Available in many industry standard colors
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Single installation seals both sides of joint
- Ideal for curtainwall, precast
- Customized to depth of substrate
Details
1/2″ to 10″
(12 – 250mm)
100% Movement (+50%/-50%)
Description
- Primary seal in paintable STPE or silicone
- Smooth convex surface
- Low cost
- Rapid install alternative to caulk & backer rod
Details
1/2″ to 1 1/4″
(12 – 30mm)
80% Movement (+30%/ -50%)
Description
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
- Many industry colors
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Description
- Pick-resistant
- Watertight and fire rated
- 2-Hour, built-in fire-rating (UL 2079)
- Seals both sides of joint
Details
1/2″ to 6″
(12 – 150mm)
100% Movement (+50%/-50%)
Stadium Interior Floors
Description
- 1 or 2-Hour, Built-In Fire-Rating (UL 2079)
- Integral coverplate
- Non-invasively anchored
Details
2″ to 10″
(50 – 250mm)
100% Movement (+50%/-50%)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 4″ (10 – 100mm)
Movement:
1 1/2″= +3/4″, -3/4″
(40mm= +20mm, -20mm)
Description
Solid aluminum
Recess mount
Heavy load rating
Details
Joint sizes up to:
3/8″ – 3″ (10 – 75mm)
Movement:
1 1/8″= +9/16″, -9/16″
(30mm= +15mm, -15mm)
Stadium Roofs
Description
- High movement
- Redundant sealing and fastening
- Double-level roof-membrane integration flanges
- UV-stable
Details
RJ-0200: 2-3 inches (50-75mm)
RJ-0400: 3-5 inches (75-125mm)
RJ-0600: 5-7 inches (125-175mm)
RJ-0800: 7-9 inches (175-225mm)
Movement
RJ-0200: 2 1/2 inches (60mm)
RJ-0400: 5 inches (125mm)
RJ-0600: 7 inches (175mm)
RJ-0800: 9 inches (225mm)
Below-grade / Foundation
Description
- Extruded Nitrile-PVC extrusion with dual-level membrane integration flanges
- Flanges are welded or adhered to below-grade waterproofing membrane and fastened with termination bar and anchors
- Transitions to RoofJoint in softscapes, and FP-Systems in hardscapes
Details
2″ up to 7″
(50 – 175mm)