Selection Guides:
Walls
Decks
Split Slab
Stadium
Fire-Rated
Roofs
Below-Grade
Immersed
Interior
WALL SYSTEMS COLORSEAL COLORSEAL Primary and Secondary Seal 50% Movement1/2" to 8" SEISMIC COLORSEAL SEISMIC COLORSEAL Primary Seal 100% Movement1/2" to 12" SEISMIC COLORSEAL-DS SEISMIC COLORSEAL DS Seals both sides of joint Primary Seal 100% Movement1" to 12" EMSHIELD WFR2 and WFR3 EMSHIELD WFR2 and WFR3 2hr built in fire rating (UL,ULC) 50% movement1" to 6" EMSHIELD SecuritySeal SSW2 SecuritySeal SSW2 Pick Resistant 2hr fire rating(UL,ULC) 50% movement1" to 6" BACKERSEAL BACKERSEAL Secondary Seal to Field Applied Liquid Sealant 50% Movement1/4" to 1 1/4"
DECKS SOLID SLAB DSM SYSTEM DSM SYSTEM Joint-face adhered Blockouts Optional55% Movement1/2" to 4" SJS SYSTEM SJS-SEISMIC JOINT SYSTEMJoint-face adheredSound dampenedIntegral coverplateUp to 100% Movement4" to 18" EMSHIELD DFR2 and DFR3 EMSHIELD DFR2 and DFR3 2hr or 3hr Built-In Fire Rating (UL,ULC) Joint-face adhered 50% Movement1/2" to 4" EMSHIELD SJS-FR1 and SJS-FR2 EMSHIELD SJS-FR1 and SJS-FR21hr or 2hr Built-In Fire Rating Sound Dampened Integral Coverplate100% movement4" to 10" EMSHIELD SecuritySeal SSF2 and SSF3 EMSHIELD SecuritySeal SSF2 and SSF3 Pick Resistant 2hr or 3hr Built-In Fire Rating (UL,ULC)50% movement1/2" to 4" HORIZONTAL COLORSEAL HORIZONTAL COLORSEALJoint-face adheredNon Trafficable100% movement1/2" to 10" THERMAFLEX THERMAFLEXBlockout-Mounted, AdheredCar, Pedestrian TrafficMovement varies by model1" to 5-1/2" max EMCRETE EMCRETEElastomeric Nosing andPatching Material1:2 Resin to Aggregate by WeightFlexible. Impact and Sound Absorbing
DECKS SPLIT SLAB MIGUTAN FP-Series MIGUTAN FP-Series Heat-Weldable Sealing InsertHeat-Weldable Waterproofing Side SheetsOptional CoverplatesMovement Varies By Model 1/2" to 6" max. Mean Joint DSM FP SYSTEM DSM FP SYSTEMSilicone-Coated, Precompressed Foam Sealing ElementOptional Coverplates55% MovementUp to 4" max. Mean Joint SJS FP SYSTEM SJS FP SYSTEM Silicone-Coated, Precompressed foam andintegral aluminum spline, sealing assemblyIntegral Coverplate 100% Movement1/2" to 18" max. Mean Joint EMSHIELD SJS-FP-FR2 SYSTEM EMSHIELD SJS-FP-FR2 SYSTEM Fire Rated, Silicone-Coated, Precompressed foam andintegral aluminum spline, sealing assemblyIntegral Coverplate 100% Movement4" to 10" max. Mean Joint
EMSHIELD FIRE-RATED EMSHIELD WFR2 and WFR3 EMSHIELD WFR2 and WFR3 2hr built in fire rating (UL,ULC) 50% movement1" to 6" EMSHIELD SecuritySeal SSW2 SecuritySeal SSW2 Pick Resistant 2hr fire rating(UL,ULC) 50% movement1" to 6" EMSHIELD DFR2 and DFR3 EMSHIELD DFR2 and DFR3 2hr or 3hr Built-In Fire Rating (UL,ULC) Joint-face adhered 50% Movement1/2" to 4" EMSHIELD SJS-FR1 and SJS-FR2 EMSHIELD SJS-FR1 and SJS-FR21hr or 2hr Built-In Fire Rating Sound Dampened Integral Coverplate100% movement4" to 10" EMSHIELD SecuritySeal SSF2 and SSF3 EMSHIELD SecuritySeal SSF2 and SSF3 Pick Resistant 2hr or 3hr Built-In Fire Rating (UL,ULC)50% movement1/2" to 4" EMSHIELD SJS-FP-FR2 SYSTEM EMSHIELD SJS-FP-FR2 SYSTEM Fire Rated, Silicone-Coated, Precompressed foam andintegral aluminum spline, sealing assemblyIntegral Coverplate 100% Movement4" to 10" max. Mean Joint
ROOFS ROOFJOINT RoofJoint Dual Flanged, Redundant Sealing, WatertightRoof Expansion Jointwith Roof To Wall Joint Transitions100% Movement2" to 4"
BELOW GRADE DSM SYSTEM DSM SYSTEM Postive Side Negative Side As Grout Containment55% Movement1/2" to 12" DSM-DS SYSTEM DSM-DS SYSTEM Negative Side with Drainage Double-Sided DSM55% Movement1/2" to 12" 20H SYSTEM 20H SYSTEM Positive Side Acrylic/Asphalt ImpregnatedPrecompressed Foam with Epoxy Adhesive50% Movement1/2" to 12" BG SYSTEM BG SYSTEM Blind Side Walls on Lagging Extruded ThermoplasticEmbeds into positive or blind-side, below-grade waterproofing membranes100% Movement2" SUBMERGED / SPECIALTY SUBMERSEAL SUBMERSEAL NSF-61 Silicone Coated PrecompressedChlorine and Saline ResistantHead Pressure Tested50% Movement1/2" to 4" DSF-SYSTEM CHEMSEAL INTERIOR ALL INTERIOR All Interior Joints IndexHeavy, Standard, and Medium DutySurface and Blockout MountedSolid Aluminum and Metal/Rubber OptionsMovement Varies With Model3/4" to 24" Surface Mounted Surface Mounted Floor JointsQuick Installation Low ProfileFlush, Carpet, Tile VersionsMovement Varies With Model3/4" to 24" QuietJoint QuietJoint Interior Partition Seal Sound, Draft, Heat, Cold, Dust BlockerSTC 53, OITC 3826 ColorsNot For Movement Joints1/2" to 6" EMSHIELD WFR2 and WFR3 EMSHIELD WFR2 and WFR3 2hr or 3hr built in fire rating (UL,ULC) 50% movement1" to 6" EMSHIELD SecuritySeal SSW2 SecuritySeal SSW2 Pick Resistant 2hr fire rating(UL,ULC) 50% movement1" to 6" EMSHIELD DFR2 and DFR3 EMSHIELD DFR2 and DFR3 2hr or 3hr Built-In Fire Rating (UL,ULC) Joint-face adhered 50% Movement1/2" to 4" EMSHIELD SJS-FR1 and SJS-FR2 EMSHIELD SJS-FR1 and SJS-FR21hr or 2hr Built-In Fire Rating Sound Dampened Integral Coverplate100% movement4" to 10" EMSHIELD SecuritySeal SSF2 and SSF3 EMSHIELD SecuritySeal SSF2 and SSF3 Pick Resistant 2hr or 3hr Built-In Fire Rating (UL,ULC)50% movement1/2" to 4" The EMSEAL CHECKLIST (For help in making a product selection, or to accompany an order click this link to open, complete, and email our new universal checklist). CHECKLIST (en español)
SUBMERGED / SPECIALTY SUBMERSEAL SUBMERSEAL NSF-61 Silicone Coated PrecompressedChlorine and Saline ResistantHead Pressure Tested50% Movement1/2" to 4" DSF-SYSTEM CHEMSEAL
INTERIOR ALL INTERIOR All Interior Joints IndexHeavy, Standard, and Medium DutySurface and Blockout MountedSolid Aluminum and Metal/Rubber OptionsMovement Varies With Model3/4" to 24" Surface Mounted Surface Mounted Floor JointsQuick Installation Low ProfileFlush, Carpet, Tile VersionsMovement Varies With Model3/4" to 24" QuietJoint QuietJoint Interior Partition Seal Sound, Draft, Heat, Cold, Dust BlockerSTC 53, OITC 3826 ColorsNot For Movement Joints1/2" to 6" EMSHIELD WFR2 and WFR3 EMSHIELD WFR2 and WFR3 2hr or 3hr built in fire rating (UL,ULC) 50% movement1" to 6" EMSHIELD SecuritySeal SSW2 SecuritySeal SSW2 Pick Resistant 2hr fire rating(UL,ULC) 50% movement1" to 6" EMSHIELD DFR2 and DFR3 EMSHIELD DFR2 and DFR3 2hr or 3hr Built-In Fire Rating (UL,ULC) Joint-face adhered 50% Movement1/2" to 4" EMSHIELD SJS-FR1 and SJS-FR2 EMSHIELD SJS-FR1 and SJS-FR21hr or 2hr Built-In Fire Rating Sound Dampened Integral Coverplate100% movement4" to 10" EMSHIELD SecuritySeal SSF2 and SSF3 EMSHIELD SecuritySeal SSF2 and SSF3 Pick Resistant 2hr or 3hr Built-In Fire Rating (UL,ULC)50% movement1/2" to 4"
The EMSEAL CHECKLIST (For help in making a product selection, or to accompany an order click this link to open, complete, and email our new universal checklist). CHECKLIST (en español)
WALL
DECK
Pick/Tamper Resistant
Chemical Resistant
Terminations & Transitions
Swimming Pool
Fountain
Viaducts
Prisons Detention Centers
Split-Slab to Solid-Slab
Schools Vandalism Areas
Expansion joints and precompressed joint sealants by EMSEAL 1-800-526-8365 -- 508-836-0280 -- techinfo@emseal.com -- Fax: 508-836-0281 EMSEAL JOINT SYSTEMS LTD. 25 Bridle Lane, Westborough, MA 01581 EMSEAL LLC. 120 Carrier Drive, Toronto, ON M9W 5R1
Last Modified: May 22, 2013
Join our Mailing List! ** Application for EMSEAL Credit ** Copyright © 1998-2013 by EMSEAL Joint Systems, Ltd. All rights reserved. This document may not be reproduced in whole or in part without permission.