Expansion Joints and Preformed Sealants from EMSEAL--Logo
www.emseal.com

      

 

Product & Application Index CAD Details Literature.MSDS
Warranty
NEWS BLOG Lead Times Tech Bulletins
Knowledge Base
REP's
Distributors

 

Project Profiles AIA/
CES
LEED HOME Company Profile R&D VIDEO FAQ Contact Us Careers SEARCH Links


SBANE 2010 Innovation Award
- Winner -

Arabic Bengali Czech Dutch Finnish French German Greek Hebrew Hindi Indonesian Italian Japanese Korean
Malaysian Norwegian Polish Portuguese PuertoRico (Spanish) Russian Simplified Chinese Spanish Swedish Thai Traditional Chinese Turkish Urdu USA/UK (English--with apologies to the Queen) Vietnamese

Structural Expansion Joints and Joint Sealants by EMSEAL
Watertight by Design Since 1959

Talk to our Tech Team:
1-800-526-8365 -- 508-836-0280 --  Fax: 508-836-0281
 techinfo@emseal.com
 

Last modified: September 02, 2010


 

Guide Specifications:
(Alphabetical by Product Name)

BACKERSEAL
BG SYSTEM
COLORSEAL
DSM SYSTEM
DSH SYSTEM
HORIZONTAL COLORSEAL
MIGUA Interior Floor & Wall

MIGUTAN Plaza & Concourse

MIGUTRANS Interior High Point Load
SEISMIC COLORSEAL

SEISMIC COLORSEAL-DS
Double Sided

SJS-SEISMIC JOINT SYSTEM
THERMAFLEX TCR
THERMAFLEX TM
20H SYSTEM
25V
 

THERMAFLEX TCR Series Guide Specification

The following guide specification is presented here is an easy-to-copy-and-paste format.

In addition, if you prefer, you may download this guide specification in .doc format by clicking this link: THERMAFLEX TCR GuideSpec (.doc).

The index at left will take you to similar guide specification pages for other EMSEAL products.


***THERMAFLEX TCR by EMSEAL GUIDE SPECIFICATION***

Application:  For Watertight Traffic Bearing Deck expansion joints     

Basis of Design:  THERMAFLEX TCR SERIES by EMSEAL

USA & INTERNATIONAL:  EMSEAL JOINT SYSTEMS, LTD, 23 Bridle Lane, Suite 3, Westborough, MA 01581-2603, Toll Free: 800-526-8365 or PH: 508-836-0280, FX: 508-836-0281, www.emseal.com.

CANADA:  EMSEAL CORPORATION, 120 Carrier Drive, Toronto, Ontario, Canada, M9W 5R1 Toll Free: 800-526-8365 or PH: 416-740-2090, FX: 416-740-0233, www.emseal.com.

Basis of Design: THERMAFLEX TCR by EMSEAL for watertight traffic bearing deck expansion joints for applications including but not limited to, parking decks, stadium and sports facility tread and riser joints, stadium and sports facility concourse joints in solid slabs, and structural expansion joints.

Expansion joint system shall be comprised of a heat-weldable, Santoprene, thermoplastic-rubber, double-celled extrusion with perforated flanges embedded in a  cold applied elastomeric nosing which shall be a two-part polyurethane material (epoxies not permitted) mixed with aggregate with sand particles not to exceed 30-mesh.  Nosing material shall be pourable grade material capable of encapsulating the perforated flanges in a single pour without the laying of a setting-bed or tack coat.  The material shall flow so as to fill voids or irregularities in concrete blockouts and beneath the perforated flanges of the gland.  Material shall cure to flexible (non-rigid) state.  So as to ensure proper mixing, flow ability, and consolidation, mixed nosing material shall have an aggregate loading ratio by weight of liquid resin to aggregate not exceeding 1:2

Physical properties of sealing gland and nosing material to be in accordance with manufacturer’s current published data. 

Final selection of the seal size to be coordinated between manufacturer, designer, and contractor(s) in consideration of expected movements as a product of structural design and expected temperature variations, taking into account as-built joint-gap sizes and temperatures at expected installation time.  Width of joint-gaps at time of casting or cutting to be adjusted, if necessary, from baseline temperature used and specified by designer in determining system suitability.

System to be installed into blockouts on each side of the joint-gap prepared to the dimensions of 20mm deep x 75mm wide (3/4" deep x 3" wide) on each side of the joint-gap.  System to be installed by qualified sub-contractors only according to detailed published installation procedures and/or in accordance with job-specific installation instructions of manufacturer’s field technician.

All terminations at ends of joints as well as all changes in plane and direction to be executed using factory-fabricated assemblies that preserve continuity of seal.  Transitions between THERMAFLEX and any other of Manufacturer’s joint systems in the vertical plane to be executed according to Manufacturer’s details and to be warranted as watertight.

***END OF GUIDE SPECIFICATION***


THERMAFLEX TCR GuideSpec (.doc)

Member:
SWRI
Sealant Waterproofing and Restoration Institute

Construction Specifications Canada

Expansion joints and precompressed joint sealants by EMSEAL

1-800-526-8365 -- 508-836-0280 --  techinfo@emseal.com -- Fax: 508-836-0281

EMSEAL JOINT SYSTEMS LTD. 25 Bridle Lane, Westborough, MA 01581
EMSEAL LLC. 120 Carrier Drive, Toronto, ON M9W 5R1

Copyright © 1998-2010 by EMSEAL Joint Systems, Ltd. All rights reserved.
This document may not be reproduced in whole or in part without permission.