Expansion Joints and Preformed Sealants from EMSEAL--Logo
www.emseal.com

      

Product & Application Index CAD Details Literature.MSDS
Warranty
In The News Factory
Lead Times
Tech Bulletins
Knowledge Base
REP's
Distributors

 

Project Profiles AIA/CES LEED HOME Company Profile R&D FAQ Contact Us Careers Search Links

Structural Expansion Joints and Joint Sealants by EMSEAL

Arabic Bengali Czech Dutch Finnish French German Greek Hebrew Hindi Indonesian Italian Japanese Korean
Malaysian Norwegian Polish Portuguese Russian Simplified Chinese Spanish Swedish Thai Traditional Chinese Turkish Urdu Vietnamese

1-800-526-8365 -- 508-836-0280 --  techinfo@emseal.com

Last modified: July 01, 2008

Founded 1959.
In North America since 1979.

ADABlue.gif (195 bytes) Flame_Icon3.gif (1305 bytes)

SWRI

27-year member: Sealant Waterproofing and Restoration Institute.  What is SWRI?

 

Guide Specifications:
(Alphabetical by Product Name)

BACKERSEAL
BG SYSTEM
COLORSEAL
DSM SYSTEM
DSH SYSTEM
HORIZONTAL COLORSEAL
MIGUA Interior Floor & Wall

MIGUTAN Plaza & Concourse

MIGUTRANS Interior High Point Load
SEISMIC COLORSEAL

SEISMIC COLORSEAL-DS
Double Sided

SJS-SEISMIC JOINT SYSTEM
THERMAFLEX TCR
THERMAFLEX TM
20H SYSTEM
25V
 

THERMAFLEX TCR Series Guide Specification

The following guide specification is presented here is an easy-to-copy-and-paste format.

In addition, if you prefer, you may download this guide specification in .doc format by clicking this link: THERMAFLEX TCR GuideSpec (.doc).

The index at left will take you to similar guide specification pages for other EMSEAL products.


***THERMAFLEX TCR by EMSEAL GUIDE SPECIFICATION***

Application:  For Watertight Traffic Bearing Deck expansion joints     

Basis of Design:  THERMAFLEX TCR SERIES by EMSEAL

USA & INTERNATIONAL:  EMSEAL JOINT SYSTEMS, LTD, 23 Bridle Lane, Suite 3, Westborough, MA 01581-2603, Toll Free: 800-526-8365 or PH: 508-836-0280, FX: 508-836-0281, www.emseal.com.

CANADA:  EMSEAL CORPORATION, 120 Carrier Drive, Toronto, Ontario, Canada, M9W 5R1 Toll Free: 800-526-8365 or PH: 416-740-2090, FX: 416-740-0233, www.emseal.com.

Basis of Design: THERMAFLEX TCR by EMSEAL for watertight traffic bearing deck expansion joints for applications including but not limited to, parking decks, stadium and sports facility tread and riser joints, stadium and sports facility concourse joints in solid slabs, and structural expansion joints.

Expansion joint system shall be comprised of a heat-weldable, Santoprene, thermoplastic-rubber, double-celled extrusion with perforated flanges embedded in a  cold applied elastomeric nosing which shall be a two-part polyurethane material (epoxies not permitted) mixed with aggregate with sand particles not to exceed 30-mesh.  Nosing material shall be pourable grade material capable of encapsulating the perforated flanges in a single pour without the laying of a setting-bed or tack coat.  The material shall flow so as to fill voids or irregularities in concrete blockouts and beneath the perforated flanges of the gland.  Material shall cure to flexible (non-rigid) state.  So as to ensure proper mixing, flow ability, and consolidation, mixed nosing material shall have an aggregate loading ratio by weight of liquid resin to aggregate not exceeding 1:2

Physical properties of sealing gland and nosing material to be in accordance with manufacturer’s current published data. 

Final selection of the seal size to be coordinated between manufacturer, designer, and contractor(s) in consideration of expected movements as a product of structural design and expected temperature variations, taking into account as-built joint-gap sizes and temperatures at expected installation time.  Width of joint-gaps at time of casting or cutting to be adjusted, if necessary, from baseline temperature used and specified by designer in determining system suitability.

System to be installed into blockouts on each side of the joint-gap prepared to the dimensions of 20mm deep x 75mm wide (3/4" deep x 3" wide) on each side of the joint-gap.  System to be installed by qualified sub-contractors only according to detailed published installation procedures and/or in accordance with job-specific installation instructions of manufacturer’s field technician.

All terminations at ends of joints as well as all changes in plane and direction to be executed using factory-fabricated assemblies that preserve continuity of seal.  Transitions between THERMAFLEX and any other of Manufacturer’s joint systems in the vertical plane to be executed according to Manufacturer’s details and to be warranted as watertight.

***END OF GUIDE SPECIFICATION***


THERMAFLEX TCR GuideSpec (.doc)

Member:
SWRI
Sealant Waterproofing and Restoration Institute

Construction Specifications Canada

Expansion joints and precompressed joint sealants by EMSEAL

Contact us through our Feedback Form; at techinfo@emseal.com; or
call us TOLL FREE: 800-526-8365 or 508-836-0280

Copyright © 1998-2008 by EMSEAL Corporation. All rights reserved.
This document may not be reproduced in whole or in part without permission.